Miller 00 Fiber Optic Laryngoscope Blade

Miller 00 Fiber Optic Laryngoscope Blade

Welch Allyn

Diagnostics
  • Green Standard ISO 7376 fiber optic laryngoscope blade compatibility.
  • Welch Allyn fiber optic blades and handles conform to ASTM F1195 and ISO 7376 3 standards (Green System).
Reusable fiber optic laryngoscope blade \u2013 Miller, size 00 (neonatal)

Description

The Welch Allyn Miller 00 Fiber Optic Laryngoscope Blade is a reusable, Green Standard (ISO 7376) stainless steel laryngoscope blade designed for neonatal and very small infant airway management. This size 00 Miller blade incorporates a removable, repolishable fiber optic light pipe that delivers bright, focused illumination when used with compatible Welch Allyn fiber optic handles. Its single-piece stainless steel construction ensures blade integrity and durability, while the repairable light pathway and free repolishing service from Welch Allyn make it a cost-effective long-term solution for hospitals and clinics. The blade has an inside vertical height of approximately 8 mm and an inside base-to-tip length of about 36 mm, making it suitable for premature and very small patients.

Bnefits

  • Size 00 Miller blade specifically designed for neonatal and very small infant airway management.
  • Green Standard (ISO 7376) fiber optic design ensures compatibility with standard green-line laryngoscope handles.
  • Single-piece stainless steel construction maintains blade integrity and minimises risk associated with soldered or brazed joints.
  • Removable, repolishable light pipe allows restoration of light output and extends the functional life of the blade.
  • Repairable light pathway means damaged or degraded light bundles can be serviced at a fraction of the cost of a complete replacement blade.
  • High-quality fiber optic bundle delivers bright, even illumination to aid visualisation of the larynx and vocal cords.
  • Reusable, non-sterile device that can be steam-sterilised according to manufacturer instructions for repeated clinical use.
  • Lightweight design with reduced handle and blade weight improves balance and manoeuvrability during difficult intubations.
  • Part of a full Welch Allyn Miller fiber optic blade range, allowing standardisation of laryngoscope equipment across sizes and patient groups.

Indications

  • Indirect visualisation of the larynx and facilitation of tracheal intubation in neonatal and very small infant patients where a Miller size 00 blade is clinically appropriate.
  • Use as part of a compatible fiber optic laryngoscope system in operating theatres, neonatal intensive care units, emergency departments and pre-hospital settings.
  • Airway management during anaesthesia, resuscitation or emergency airway access in neonates and premature infants, when performed by appropriately trained clinicians.

Composition

  • Material: Stainless steel (grade 304 as specified for Welch Allyn Miller fiber optic blades).
  • Fiber optic light bundle encased in a removable light pipe.
  • Green ISO 7376 standard universal connector at the proximal end for fiber optic handle compatibility.

Formulation

  • Reusable, non-sterile fiber optic laryngoscope blade.
  • Miller straight blade profile with flattened tongue for sweeping the tongue aside and improving field of view.
  • Size 00 geometry: approximately 8 mm inside vertical height and 36 mm length from base to tip.
  • Single-piece stainless steel blade body with integrated mounting block and Green Standard (ISO 7376) fitting.
  • Removable fiber optic light pipe positioned along the blade to transmit light from the handle to the distal tip.

Packaging

  • Typically supplied as a single Miller 00 fiber optic blade per package.
  • Delivered non-sterile in protective packaging; must be cleaned and sterilised prior to first clinical use.
  • Labelling includes manufacturer name (Welch Allyn), part number (68065), device description, size, and relevant regulatory/safety information.

Usage

  • Before first use and between patients, thoroughly clean and sterilise the blade in accordance with Welch Allyn’s reprocessing instructions and local infection prevention policies.
  • Inspect the blade and light pipe before each use for cleanliness, damage, corrosion, cracked fibers or other defects; do not use if any damage is evident.
  • Attach the blade securely to a compatible Green Standard (ISO 7376) Welch Allyn fiber optic handle, ensuring proper engagement of the locking mechanism.
  • Verify that the light source is functioning and that adequate illumination is delivered to the distal tip before bringing the blade into contact with the patient.
  • Use only clinicians with appropriate training and competence in neonatal laryngoscopy and tracheal intubation to perform procedures with this device.
  • After use, remove the blade from the handle, follow the recommended cleaning and decontamination protocol (including disassembly of the light pipe if required), and sterilise according to manufacturer guidance.
  • Periodically assess the brightness of the fiber optic bundle; if light output is significantly reduced after repeated sterilisation cycles, arrange for repolishing or repair through authorised Welch Allyn service channels.
  • Store the blade in a clean, dry area or dedicated laryngoscope storage case when not in use.

Contraindications

  • Do not use for patient intubation without appropriate clinical training and competence in laryngoscopy and airway management.
  • Not intended for use in patients for whom a Miller size 00 blade is clinically inappropriate (e.g. larger infants, children or adults who require larger blade sizes).
  • Do not use if the blade or light pipe is visibly damaged, corroded, bent, has loose components, or shows significant fiber optic breakage or inadequate illumination.
  • Not designed for single-use; however, when reprocessing conditions cannot be met or the device cannot be adequately cleaned and sterilised, it should not be reused.
  • Do not use with non-compatible laryngoscope handles or non-standard light sources that may not meet ISO 7376 Green Standard requirements.

Adverse Effects

  • As with all laryngoscope blades, improper use can cause trauma to the lips, teeth, tongue, oropharynx, larynx or upper airway structures.
  • Potential for dental damage if excessive leverage is applied against the upper incisors.
  • Risk of soft tissue bruising, laceration or bleeding in the oropharynx if inserted or manipulated incorrectly.
  • If reprocessing instructions are not followed, there is a risk of cross-contamination or infection transmission between patients.

Storage Conditions

  • Store the cleaned and sterilised blade in a dry, clean environment, ideally in a dedicated laryngoscope storage case or tray.
  • Protect from impact, bending or dropping to avoid damage to the stainless steel blade or fiber optic light pipe.
  • Avoid prolonged exposure to corrosive chemicals or environments that may damage stainless steel or optical components.
  • Ensure the blade is completely dry before storage to minimise risk of corrosion or microbial growth.

Duration

Not applicable \u2013 this is a reusable diagnostic/airway management instrument used episodically during procedures rather than over a defined treatment course.

Onset

Not applicable in a pharmacological sense; illumination and mechanical function are immediate when the blade is correctly attached to a powered fiber optic handle.

Browse more Diagnostics

ELI 150c Resting Electrocardiograph

ELI 150c Resting Electrocardiograph

Medisave

ELI 150c Resting Electrocardiograph

Medical and Aesthetic Equipment
  • £4,822.79
  • £4,078.79
  • 5 more

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medisave

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medical and Aesthetic Equipment
  • £25.99
  • £28.99
  • 7 more

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medisave

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medical and Aesthetic Equipment
  • £3,091.19
  • £2,762.39
  • 3 more

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry \u2013 Plug 4

Medisave

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Medical and Aesthetic Equipment
  • £736.79
  • £571.19
  • 3 more

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medisave

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medical and Aesthetic Equipment
  • £5.49
  • £35.99
  • 2 more

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

ProBP\u2122 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medisave

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medical and Aesthetic Equipment
  • £87.59
  • £257.99
  • 2 more

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medisave

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medical and Aesthetic Equipment
  • £2,279.99
  • £2,243.99
  • 0 more

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medisave

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medical and Aesthetic Equipment
  • £80.39
  • £64.79
  • 1 more

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medisave

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medical and Aesthetic Equipment
  • £1,689.59
  • £1,919.99
  • 0 more

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medisave

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medical and Aesthetic Equipment
  • £46.79
  • £56.39
  • 1 more

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medisave

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medical and Aesthetic Equipment
  • £32.39
  • £14.39
  • 1 more

Mobile Stand for Welch Allyn Vital Signs Monitor

Mobile Stand for Welch Allyn Vital Signs Monitor

Medisave

Mobile Stand for Welch Allyn Vital Signs Monitor

Medical and Aesthetic Equipment
  • £148.79
  • £140.35
  • 1 more